Sign In | Join Free | My himfr.com
Home > Emc Anechoic Chamber >

Up To 40GHz Electromagnetic Testing Rf Absorbers Anechoic Test Chamber

Changzhou Haozhuo Electronic Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Up To 40GHz Electromagnetic Testing Rf Absorbers Anechoic Test Chamber from wholesalers
     
    Buy cheap Up To 40GHz Electromagnetic Testing Rf Absorbers Anechoic Test Chamber from wholesalers
    • Buy cheap Up To 40GHz Electromagnetic Testing Rf Absorbers Anechoic Test Chamber from wholesalers
    • Buy cheap Up To 40GHz Electromagnetic Testing Rf Absorbers Anechoic Test Chamber from wholesalers
    • Buy cheap Up To 40GHz Electromagnetic Testing Rf Absorbers Anechoic Test Chamber from wholesalers
    • Buy cheap Up To 40GHz Electromagnetic Testing Rf Absorbers Anechoic Test Chamber from wholesalers
    • Buy cheap Up To 40GHz Electromagnetic Testing Rf Absorbers Anechoic Test Chamber from wholesalers
    • Buy cheap Up To 40GHz Electromagnetic Testing Rf Absorbers Anechoic Test Chamber from wholesalers

    Up To 40GHz Electromagnetic Testing Rf Absorbers Anechoic Test Chamber

    Ask Lasest Price
    Model Number : H
    Brand Name : haozhuo
    Supply Ability : 1 Set/Sets per Month
    Price : $10,000.00
    Certification : CE RoHS
    • Product Details
    • Company Profile

    Up To 40GHz Electromagnetic Testing Rf Absorbers Anechoic Test Chamber

    up to 40GHz High Performance EMC Testing Chamber

    Upon request, RF shielded rooms can be lined with plasterboard walls and a suspended ceiling. The floor of the shield room can be constructed using wood with a vinyl topping flush to the door threshold. In a control room or data center, the floor can be constructed as a raised computer floor to enable easy cable routing. The raised computer floor is constructed using standard anti-static floor tiles onto adjustable pedestals in order to withstand a minimum average floor load of 500 kg/m2. A raised computer floor system provides a flush and threshold-less entrance to the control or amplifier room when the chamber is built inside a floor pit.


    When a shielded room is necessary?
    · If your lab is near a broad spectrum emitter (i.e equipment that transmits multiple frequencies under 400Hz), radio tower, mobile phone transmitter or other large field generators, then you should consider a shielded room.
    · If your research is in the gamma band and you do not want to use a 60/50Hz notch filter to remove mains power noise, you might consider a shielded room. We recommend taking the steps above to first minimize the mains power noise. If that is not sufficient for your needs, then a shielded room may help.

    Product Features
    Shielding panels are made of molded cold-rolled steel plates. They are jointed in way and welded with CO2 protection, which can restrain the plates from distortion and ensure the leveling of the steel plates.
    Self-supported frame construction is made of section materials.
    Shielding door is optional: standard electromotive door (electromotive / manual alternative), full-automatic shielding door (light-activated with password) sliding door. Subshining stainless steel decoration is on surface of the door. Standard dimension of the door is:0.85×2(m).
    Large-scale hanging sliding shielding-door, electromotive sliding push-in door, electromotive sliding gasbag door, rotated door with track.
    Ventilated window is designed in cellular wave-guide type with dimension:300×300(mm).
    Power filter is in condition of high-performance and low-leakage.
    Telephone, air-conditioning, fire-fight devices, optical fiber and CAT5 cables can be equipped customized.
    Decoration will be arranged in the shielding room according to standard equipment room requirements.
    Shielding Properties (dB)


    Magnetic field

    14kHz85dB
    100KHz100dB
    200KHz110dB
    Plane wave50-103MHz120dB


    Microware

    1-10GHz110dB
    10-20GHz100dB
    20-40GHz80dB
    Application Scope
    EMC tesing
    Items 1Module Panel type, 2mm/3mm galvanized steel plate
    Items 2RF Shielding Door, Open size:1000*2000mm
    Or Customized dimension
    Items 3Power Filters
    16A/ 32A/50A/63A
    Or Customized parameter
    Items 4Honeycomb Ventilation panels
    300x300x25mm
    300x600x25mm
    Or Customized dimension
    Items 5RF Panel
    300*200mm,including waveguide Ø4cm / L220cm x1 BNC*2/N*2/SMA*2
    Or Customized dimension
    Items 6Floor
    Anti-static floor or Laminate flooring
    Or customized materials
    Items 7Foam RF absorber
    Ferrite tile
    High power absorber
    Items 8Beryllium copper Fingers
    Items 9Steel waveguide
    Items 10EMI Shielding Gasket


    RF Anechoic chamber Shielding Properties (dB)


    Magnetic field

    14kHz75dB
    100KHz100dB
    200KHz110dB
    Plane wave50-103MHz120dB


    Microware

    1-10GHz110dB
    10-20GHz

    100dB

    Up To 40GHz Electromagnetic Testing Rf Absorbers Anechoic Test ChamberUp To 40GHz Electromagnetic Testing Rf Absorbers Anechoic Test Chamber























    Quality Up To 40GHz Electromagnetic Testing Rf Absorbers Anechoic Test Chamber for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Changzhou Haozhuo Electronic Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)